Data Centre Power Generation
Amazon, Dublin Thermal and airflow simulation of 24MW power generation enclosure to provide efficient passive cooling, avoiding generator derating. New Build. Passive Design • Thermal Simulation • Performance Analysis • CFD |
|
Clare County Council HQ
Ennis, Co. Clare Full Design and implementation of Natural Ventilation & control system commissioning. Passive Design • Thermal Simulation • Natural Ventilation • Performance Analysis • CFD |
|
Speculative Office Complex
Cuffe Street, Dublin USGBC LEED Gold facade design and compliance of air conditioned office complex. New Build. Passive Design • Thermal Simulation • Performance Analysis • CFD |
|
Large Suburban Residential Complex
Carrickmines, Dublin Airflow/wind analysis through large suburban development. New Build. Large External Site CFD |
|
Government Department Offices
Intreo, Galway Full Design and implementation of cellular Natural Ventilation & control system commissioning. New Build. Passive Design • Thermal Simulation • Natural Ventilation • Performance Analysis • CFD |
|
Speculative Office Complex
Co. Meath Overheating, Shading, and Daylight analysis. New Build. Passive Design • Thermal Simulation • Design Validation • Performance Analysis • Daylight Simulation |
|
Double Skin Facade
Messian Plaza, Dublin CFD Analysis of Double-Skin-Facade detail on landmark commercial building in Dublin. Passive Design • Thermal Simulation • Design Validation • Performance Analysis • CFD |
|
Community Care Centre
Birr, Co Offaly Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building. Passive Design • Design Validation • Performance Analysis |
|
Smoke/Fire Analysis
Bewleys Cafe, Grafton Street, Dublin Fire & smoke CFD analysis of landmark commercial building in Dublin. Mechanical extract and airflow analysis. Building Refurbishment. Passive Design • Thermal Simulation • Design Validation • Performance Analysis • CFD |
|
Road Safety Authority HQ
RSA, Ballina Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building. Passive Design • Thermal Simulation • Design Validation • Performance Analysis |
|
National Parks & Wildlife Service
Ballycroy Visitor Centre Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building. Passive Design • Thermal Simulation • Natural Ventilation • Design Validation • Performance Analysis • CFD |
|
Government Buildings
Galway City, Co. Galway Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building. Performance Analysis |
|
Primary Care Centre
Mallow, Co. Cork Full Design & automated control of naturally ventilated Care Centre. New Build. Passive Design • Thermal Simulation • Natural Ventilation • CFD |
|
Facade Design
State Street Bank, Dublin Facade/shading design & material selection. New Build. Thermal Simulation • Design Validation • CFD |
|
Open Plan Office Development (HVAC) - Irish Times, Dublin
Thermal Analysis and HVAC design of commercial offices. New Build. Thermal Simulation • Design Validation • CFD |
|
Open Plan Office Development
Bank of Ireland, Dublin HVAC, Active Chilled Beams. Thermal Analysis, Material Selection, Shading and HVAC Design of commercial offices. New Build. Passive Design • Thermal Simulation • CFD |
|
Dept of Agriculture, Food and the Marine
National Seafood Centre, Co. Cork Thermal Analysis, Solar Shading, Design Validation and Natural Ventilation Compliance. New Build. Passive Design • Thermal Simulation • Natural Ventilation • CFD |
|
NUIM Library Building (NV/Mixed Mode)
Maynooth, Co. Kildare Thermal Analysis and Natural Ventilation Design Validation of library building and double skin facade (DSF). New Build. Thermal Simulation • Natural Ventilation • Design Validation • CFD |
|
Irish Prison Service Headquarters - Co. Longford, Ireland
Thermal Analysis, Solar Shading, Design Validation and Natural Ventilation Compliance. New Build. Passive Design • Thermal Simulation • Natural Ventilation • Design Validation • Performance Analysis • CFD |
|
Open Plan Office Development
Cork City Thermal Analysis and HVAC design of commercial offices. New Build. Thermal Simulation • Design Validation • CFD |
|
Municipal Space & Offices
Dublin City Thermal Analysis, Material Selection and Shading of public spaces and offices. New Build. Passive Design • Thermal Simulation |
|
Impact of Commercial Development on Dwellings
Daylight analysis, impact of commercial proposal on existing dwellings. New Build. Design Validation |
|
Open Plan Office
Thermal Analysis, Material Selection and Shading of commercial offices, Co. Dublin New Build. Thermal Simulation • Design Validation • CFD |
The process of Passive Design sets out to reduce or eliminate the requirement for mechanical heating, ventilation & air-conditioning (HVAC) systems.
During the early stages of design EDS® will assist the architect in achieving a passive design and determine potential savings around design proposals.
The balance of maximising daylight to occupied zones while prohibiting solar gains will also help to reduce electrical lighting & cooling demands, promoting a comfortable working/living space.
Climate and other environmental conditions such as rainwater availability, prevailing wind directions, solar radiation, and night cooling will be used to condition the internal environment.
The biggest savings may be realised by the implementation of Natural Ventilation (NV) early in the design process. EDS® NV successfully eliminates the requirement for air-conditioning and mechanical ventilation on many large and medium sized buildings using carefully calculated implementation of natural ventilation techniques; supported by computational fluid dynamic (CFD) calculation methods.
Computer simulation can be used to establish benefits or limitations in advance of changes to design proposals; or changes to the existing built environment. The calculation methods that are typically adopted include:
- Steady State Calculations
More »